Thai University RankingsRESEARCH RADAR
← Back to research database
งานใหม่ที่น่าจับตา

Association Between Bladder Volume Changes and Organ-at-Risk Dose Constraints in a Moderate Hypofractionation for Prostate Cancer

IMPACT SIGNAL74/100
01

Information from the abstract

Background: The aim of the study was to evaluate the association between bladder volume and dose-volume constraints of organs at risk—specifically the bladder and rectum—in patients receiving moderately hypofractionated radiotherapy for localized prostate cancer, and to identify factors associated with exceeding organs-at-risk dose constraints. Methods: This retrospective study included patients who received either 70 Gy in 28 fractions or 60 Gy in 20 fractions using volumetric modulated arc therapy with daily cone beam computed tomography. Bladder volume was measured at each session. Multilevel mixed-effects linear regression was used to assess the association between bladder volume and organs-at-risk dose constraints. Zero-inflated Poisson regression was applied to explore factors associated with organs-at-risk dose overdose, defined according to the Radiation Therapy Oncology Group (RTOG) 0415 and Conventional or Hypofractionated High Dose Intensity Modulated Radiotherapy in Prostate Cancer (CHHiP) trial thresholds. Results: A total of 388 radiotherapy sessions were analyzed among 15 patients. Increased bladder volume was significantly associated with reduced radiation exposure to organs at risk. This protective effect was more pronounced for the urinary bladder (risk difference: −6.4% to −7.8% per 100 mL increase) than for the rectum (−1.0% to −2.2%) under the 70 Gy protocol. No significant rectal protection was observed under the 60 Gy protocol. The 60 Gy protocol (risk ratio = 15.4; 95% confidence interval, 2.93–81.02) and high recurrence risk (risk ratio = 2.41; 95% confidence interval, 1.12–5.16) were significant predictors of bladder overdose. The 60 Gy protocol was the only significant predictor of rectal overdose. Conclusions: Larger bladder volumes reduce radiation exposure to organs at risk, particularly the urinary bladder. Rectal protection was limited, especially under the 60 Gy protocol. Optimizing bladder volume may improve treatment safety and adherence to dose constraints.

02

Why this record is monitored

This record has an Impact Signal of 74/100 based on recency, source, collaboration, and bibliographic signals. It prioritizes monitoring and is not a judgment of research quality.

Related topics: Prostate Cancer Diagnosis and Treatment · Urinary Bladder and Prostate Research · Advanced Radiotherapy Techniques

03

Thai researcher and institutional participation

Natcha Senawin · Suppadech Tunruttanakul · Sorathan Chanjorahke · Phruetiporn Thainsitiporn · Sasiprapa Niamsawan · Jayanton Patumanond · Charoenkrung Pracharak Hospital · Nakhon Sawan Rajabhat University · Thai Health Promotion Foundation · Naresuan University

04

Data limitations

This page is a bibliographic record based on abstract-level information, not a full analysis or quality assessment. Verify the DOI and original article before citation.