Thai University RankingsRESEARCH RADAR
← กลับฐานข้อมูลงานวิจัย
มีศักยภาพระดับโลก

Community thermal energy storage, a cost-effective pathway for the decarbonisation of suburban cooling in Australia

Community thermal energy storage, a cost-effective pathway for the decarbonisation of suburban cooling in Australia

สัญญาณผลกระทบ83/100
01

ข้อมูลจากบทคัดย่อ

ยังไม่มีสรุปภาษาไทยสำหรับระเบียนนี้
ด้านล่างเป็นบทคัดย่อต้นฉบับภาษาอังกฤษจากข้อมูลบรรณานุกรม โปรดตรวจบทความต้นฉบับก่อนอ้างอิง

Residential cooling demand in Australia is increasing due to rising temperatures, urban infill, and improved building insulation that traps internal heat. Solar photovoltaic (PV) generation combined with onsite energy storage presents a promising pathway to decarbonise cooling loads; however, the optimal configuration at a neighbourhood scale remains unclear. This study conducts a comparative assessment of three cooling strategies in a suburban Australian context: (i) individual systems, where each household operates stand-alone PV and storage; (ii) district systems, where cooling and storage are centralised; and (iii) community shared systems, where storage is centralised but households have their own cooling. Each configuration integrates individual PV generation. Energy storage is implemented either as battery storage or thermal energy storage (TES), playing a critical role in enabling load shifting, improving PV self-consumption, and reducing reliance on grid electricity by temporally decoupling cooling demand from solar generation availability. A detailed TRNSYS simulation model was developed using high-resolution meteorological, load, and tariff data for an Australian suburb. System performance was evaluated in terms of energy consumption, primary energy saving, life cycle cost, storage utilisation efficiency, grid export minimisation, PV self-consumption rate, and peak reduction. Among six configurations, the district cooling system with centralised battery achieves the highest primary energy saving (98.6%) and almost eliminates grid imports but also exhibits the highest life cycle cost (USD 1.36 million). In contrast, the community system with thermal energy storage achieved a balanced performance, delivering 86.1% primary energy saving at the lowest life cycle cost of USD 0.55 million, making it the most cost-effective solution for this suburban community. By jointly evaluating individual, district, and community cooling architectures with both battery and PCM storage under a common Australian framework, this study clarifies the techno-economic trade-offs of neighbourhood-scale PV-integrated cooling and highlights community TES as a cost-effective pathway for reducing grid electricity dependence and associated primary energy demand, thereby contributing to the transition towards net-zero energy systems at the suburban scale.

02

เหตุผลที่อยู่ในฐานติดตาม

ระเบียนนี้ได้รับ Impact Signal 83/100 จากความใหม่ แหล่งเผยแพร่ ความร่วมมือ และสัญญาณในข้อมูลบรรณานุกรม คะแนนนี้ใช้จัดลำดับการติดตาม ไม่ใช่การตัดสินคุณภาพงานวิจัย

ประเด็นที่เกี่ยวข้อง: Integrated Energy Systems Optimization · Thermodynamic and Exergetic Analyses of Power and Cooling Systems · Smart Grid Energy Management

03

บทบาทของนักวิจัยและสถาบันไทย

Benjapon Chalermsinsuwan · Chulalongkorn University

04

ข้อจำกัดของข้อมูล

หน้านี้เป็นระเบียนบรรณานุกรมและข้อมูลจากบทคัดย่อ ยังไม่ใช่บทวิเคราะห์ฉบับเต็มหรือการประเมินคุณภาพงานวิจัย ควรตรวจสอบ DOI และเอกสารต้นฉบับก่อนนำไปอ้างอิง