Thai University RankingsRESEARCH RADAR
← กลับฐานข้อมูลงานวิจัย
งานใหม่ที่น่าจับตา

Ethical and regulatory aspects of facial scanning in dentistry: a scoping review

Ethical and regulatory aspects of facial scanning in dentistry: a scoping review

สัญญาณผลกระทบ72/100
01

ข้อมูลจากบทคัดย่อ

ยังไม่มีสรุปภาษาไทยสำหรับระเบียนนี้
ด้านล่างเป็นบทคัดย่อต้นฉบับภาษาอังกฤษจากข้อมูลบรรณานุกรม โปรดตรวจบทความต้นฉบับก่อนอ้างอิง

OBJECTIVES: To provide an overview of facial scanners and scanning applications used in dentistry, focusing on clinical validation, certification status, and to identify ethical and regulatory concerns. MATERIALS AND METHODS: A literature search was performed with eligibility criteria that included studies in dentistry that used at least one facial scanner or smartphone scanning application in human facial region in any language. Scanners and applications identified from literature and International Dental Show 2025 were manually noted, and subsequently searched for detailed certification (medical, general, others) and technical information. Furthermore, studies explicitly/implicitly mention/discuss ethical and/or regulatory concerns were included. RESULTS: Ninety-five scanners and 23 smartphone-based applications were identified, of which 90 scanners and all applications were clinically validated. Six scanners (6%, FusionFaceScanner, Carestream CS9600, Planmeca ProFace, Planmeca ProMax 3D Mid, Planmeca ProMax 3D ProFace, Planmeca Viso G7) were Medical Device Regulation-certified, 49% held other certifications, and 51% had unverifiable certification status. Among 19,789 records, six scientific studies discussed ethical concerns, including ethical approval, informed consent, privacy, accuracy, and medical regulatory obligations. CONCLUSION: Despite validation, publicly accessible, verifiable medical-related certification remained limited among the identified scanners, highlighting that ethical and regulatory considerations are underreported in the scientific literature rather than absent from clinical practice. Informed consent, data privacy, accuracy, and medical device compliance were addressed in the included studies. CLINICAL RELEVANCE: As facial scans provide comprehensive information for esthetic- and facial-driven treatment planning, the findings of this study highlight the need for practitioners and researchers to remain cautious regarding device safety, regulatory compliance, and technological limitations.

02

เหตุผลที่อยู่ในฐานติดตาม

ระเบียนนี้ได้รับ Impact Signal 72/100 จากความใหม่ แหล่งเผยแพร่ ความร่วมมือ และสัญญาณในข้อมูลบรรณานุกรม คะแนนนี้ใช้จัดลำดับการติดตาม ไม่ใช่การตัดสินคุณภาพงานวิจัย

ประเด็นที่เกี่ยวข้อง: Dental Research and COVID-19 · Digital Imaging in Medicine · Dental Radiography and Imaging

03

บทบาทของนักวิจัยและสถาบันไทย

Thanatchaporn Jindanil · Chulalongkorn University

04

ข้อจำกัดของข้อมูล

หน้านี้เป็นระเบียนบรรณานุกรมและข้อมูลจากบทคัดย่อ ยังไม่ใช่บทวิเคราะห์ฉบับเต็มหรือการประเมินคุณภาพงานวิจัย ควรตรวจสอบ DOI และเอกสารต้นฉบับก่อนนำไปอ้างอิง