Background: Centrifugation-based hematocrit (Hct) testing remains widely used in decentralized primary care settings where access to automated hematology analyzers may be limited. Appropriate proficiency testing (PT) performance assessment therefore requires consideration of the analytical variability associated with this measurement method. This study evaluated longitudinal PT data to characterize method-specific variability and compare alternative approaches to RSD estimation for centrifugation-based Hct testing. Methods: Seventy-two datasets from 32 PT rounds conducted during 2017–2024 were analyzed, with 12 to 310 participants per dataset. PT materials were assessed for homogeneity and stability in accordance with ISO 13528. The relative standard deviation (RSD) was estimated using two approaches: Method A, based on all statistically processed valid results to reflect total interlaboratory variability, and Method B, based on the satisfactory-performance subset (∣z∣ ≤ 2), within which robust statistics were recalculated. Temporal trends were evaluated by linear regression using dataset-specific RSD values. Sensitivity analysis evaluated Method B using alternative z-score inclusion thresholds of ∣z∣ ≤ 1.5, 2.0, 2.5, and 3.0. Performance classifications in 2024 were compared descriptively. Results: All PT materials met predefined homogeneity and stability criteria. The final cumulative pooled relative standard deviation (RSDpooled) was 10.81% for Method A and 4.86% for Method B. was 10.81% for Method A and 4.86% for Method B. Method A showed an increasing temporal trend, whereas Method B showed minimal temporal change; however, participant numbers increased substantially over the study period and may have contributed to the Method A trend. Sensitivity analysis showed that Method B was threshold-dependent, with final RSDpooled values of 3.90%, 4.86%, 5.59%, and 6.28% at ∣z∣ ≤ 1.5, 2.0, 2.5, and 3.0, respectively. In the 2024 datasets, satisfactory rates ranged from 75.68–99.12% for Method A and 43.15–95.61% for Method B. Conclusions: Methods A and B provide complementary information whereas Method B characterizes dispersion among participants meeting a predefined satisfactory-performance criterion. The Method B RSDpooled of 4.86% is specific to inclusion criterion and should not be interpreted as a threshold-independent estimate of analytical imprecision. Further studies using prospectively defined statistical methods and appropriately structured participant-level data are needed to determine its potential utility for PT/EQA performance assessment.
เหตุผลที่อยู่ในฐานติดตาม
ระเบียนนี้ได้รับ Impact Signal 78/100 จากความใหม่ แหล่งเผยแพร่ ความร่วมมือ และสัญญาณในข้อมูลบรรณานุกรม คะแนนนี้ใช้จัดลำดับการติดตาม ไม่ใช่การตัดสินคุณภาพงานวิจัย
ประเด็นที่เกี่ยวข้อง: Clinical Laboratory Practices and Quality Control · Scientific Measurement and Uncertainty Evaluation · Reliability and Agreement in Measurement
บทบาทของนักวิจัยและสถาบันไทย
Watcharinthon Theansun · Kunchit Kongros · Napaporn Apiratmateekul · Ornuma Haonon · Munthana Wadthaisong · Gerald J. Kost · Wanvisa Treebuphachatsakul · Naresuan University
ข้อจำกัดของข้อมูล
หน้านี้เป็นระเบียนบรรณานุกรมและข้อมูลจากบทคัดย่อ ยังไม่ใช่บทวิเคราะห์ฉบับเต็มหรือการประเมินคุณภาพงานวิจัย ควรตรวจสอบ DOI และเอกสารต้นฉบับก่อนนำไปอ้างอิง